An Evaluation of the Potential Use of Non-nuclear Density Gauges for Asphalt Concrete Acceptance

Download An Evaluation of the Potential Use of Non-nuclear Density Gauges for Asphalt Concrete Acceptance PDF Online Free

Author :
Release : 2011
Genre : Asphalt concrete
Kind :
Book Rating : /5 ( reviews)

An Evaluation of the Potential Use of Non-nuclear Density Gauges for Asphalt Concrete Acceptance - read free eBook in online reader or directly download on the web page. Select files or add your book in reader. Download and read online ebook An Evaluation of the Potential Use of Non-nuclear Density Gauges for Asphalt Concrete Acceptance write by Alex K. Apeagyei. This book was released on 2011. An Evaluation of the Potential Use of Non-nuclear Density Gauges for Asphalt Concrete Acceptance available in PDF, EPUB and Kindle. This report describes the results of a study using non-nuclear density gauges (NNDGs) to measure the in-situ density of asphalt concrete (AC) material in Virginia. The study compared the NNDG results with those obtained from the use of two traditional AC density acceptance methods: the core method (AASHTO T 166) and the nuclear density gauge (NDG) method. Although these two methods are the most widely used methods of accepting AC density, the core method is time-consuming and destructive and involves bulky test setups and the NDG method, although portable and non-destructive, is associated with safety concerns related to the presence of radioactive materials in the gauge. The purpose of the study was to evaluate the use of two NNDGs as a potentially safe, portable, and expedient method of measuring AC density-a key indicator of pavement performance. The direct comparison of NNDG and core density and the acceptance rates with the use of NNDGs and NDGs were the focus of the study. Extensive field and laboratory tests were conducted to determine AC density using two models of NNDGs (i.e., the Troxler PaveTracker Plus and the TransTech Model PQI 301) and one model of an NDG (i.e., the Troxler Model 4640-B). Density measurements of AC cores/plugs taken at gauge testing locations were conducted in the laboratory in accordance with AASHTO T 166 for comparisons. The results of the field testing showed that NNDG measurements were not well correlated with core density or NDG measurements. However, there was good agreement between readings from NNDGs and NDGs in terms of identifying core cutting locations (67%), control strip acceptance (75%), and test section acceptance (95%). This apparent contradiction between the acceptance rate among the gauges and the poor correlation could be explained by the relatively low ranges in measured field density (0-5 lb/ft3), which is within the precision ranges of the gauges used. The results of additional laboratory testing of 10 AC slabs with air void contents ranging from about 3% to 20% confirmed the results of the field testing. Specifically, they demonstrated that compared with NDGs, NNDGs were less sensitive, with an average relative bias of 19.6 lb/ft3 and 9.6 lb/ft3 for the PQI 300 and the PaveTracker Plus, respectively, compared with 2.2 lb/ft3 for the NDG. The results also showed that results from use of the NNDGs were not well correlated with core density measured in accordance with AASHTO T 166, which is generally accepted as the most accurate method of measuring density. The study concludes that NNDGs of the types used in the study are not suitable for measuring AC density for acceptance purposes and thus are not recommended for use as density acceptance tools in Virginia.

Evaluation of Non-destructive Density Determination for QA/QC Acceptance Testing

Download Evaluation of Non-destructive Density Determination for QA/QC Acceptance Testing PDF Online Free

Author :
Release : 2018
Genre : Civil engineering
Kind :
Book Rating : /5 ( reviews)

Evaluation of Non-destructive Density Determination for QA/QC Acceptance Testing - read free eBook in online reader or directly download on the web page. Select files or add your book in reader. Download and read online ebook Evaluation of Non-destructive Density Determination for QA/QC Acceptance Testing write by David Mata (P.E.). This book was released on 2018. Evaluation of Non-destructive Density Determination for QA/QC Acceptance Testing available in PDF, EPUB and Kindle.

Evaluation of New Nuclear Density Gauges on Asphalt Concrete

Download Evaluation of New Nuclear Density Gauges on Asphalt Concrete PDF Online Free

Author :
Release : 1991
Genre : Pavements, Asphalt concrete
Kind :
Book Rating : /5 ( reviews)

Evaluation of New Nuclear Density Gauges on Asphalt Concrete - read free eBook in online reader or directly download on the web page. Select files or add your book in reader. Download and read online ebook Evaluation of New Nuclear Density Gauges on Asphalt Concrete write by Garnell Belt. This book was released on 1991. Evaluation of New Nuclear Density Gauges on Asphalt Concrete available in PDF, EPUB and Kindle. This report documents an evaluation of the state-of-the-art capabilities of nuclear density gauges to monitor the density of asphalt concrete. In particular, providing immediate information on compaction by the use of roller-mounted gauges and measuring the densities of thin layers were addressed. The study included three phases: literature search, laboratory tests, and field trials.

A Working Review of Available Non-nuclear Equipment for Determining In-place Density of Asphalt

Download A Working Review of Available Non-nuclear Equipment for Determining In-place Density of Asphalt PDF Online Free

Author :
Release : 2005
Genre : Pavements, Asphalt
Kind :
Book Rating : /5 ( reviews)

A Working Review of Available Non-nuclear Equipment for Determining In-place Density of Asphalt - read free eBook in online reader or directly download on the web page. Select files or add your book in reader. Download and read online ebook A Working Review of Available Non-nuclear Equipment for Determining In-place Density of Asphalt write by Shad M. Sargand. This book was released on 2005. A Working Review of Available Non-nuclear Equipment for Determining In-place Density of Asphalt available in PDF, EPUB and Kindle. Current non-nuclear methods of measuring asphalt pavement density use electrical properties of asphalt. Two known instruments, the PaveTrackerTM and the PQI Model 300, estimate pavement density by inferring the relative proportion of air-filled voids in the asphalt from a measure of dielectric permittivity. Under this project, currently available and new methods of determining in-place asphalt density were investigated. The investigation included a laboratory study of the PaveTrackerTM's ability to accurately measure density under a variety of conditions, including coarse or fine aggregate in mix, presence of internal and/or surface moisture, sample area, and sample depth. Both the PaveTrackerTM and the PQI Model 300 were evaluated in the field by measuring density of measurement locations at each of 24 project sites and comparing to corresponding values measured by a nuclear gauge and laboratory tests. Recommendations for practice, including expected payoff results in using them, are given.

Investigation of a Non-destructive System to Evaluation Critical Properties of Asphalt

Download Investigation of a Non-destructive System to Evaluation Critical Properties of Asphalt PDF Online Free

Author :
Release : 2013
Genre : Pavements
Kind :
Book Rating : /5 ( reviews)

Investigation of a Non-destructive System to Evaluation Critical Properties of Asphalt - read free eBook in online reader or directly download on the web page. Select files or add your book in reader. Download and read online ebook Investigation of a Non-destructive System to Evaluation Critical Properties of Asphalt write by Robert L. Schmitt (Ph.D.). This book was released on 2013. Investigation of a Non-destructive System to Evaluation Critical Properties of Asphalt available in PDF, EPUB and Kindle.